Fluid-structure coupling analysis and simulation of viscosity effect on Coriolis mass flowmeter

Page view(s)
0
Checked on
Fluid-structure coupling analysis and simulation of viscosity effect on Coriolis mass flowmeter
Title:
Fluid-structure coupling analysis and simulation of viscosity effect on Coriolis mass flowmeter
Journal Title:
International Journal of Aerospace and Lightweight Structures
OA Status:
closed
Keywords:
Publication Date:
01 December 2013
Citation:
Abstract:
Coriolis mass flowmeters (CMFs) are increasingly used in the oil and gas industry with feature of directly measuring mass flow rate. The performance of CMFs influenced by on-line viscosity still needs further study. A computational fluid dynamics model of U-shape CMF was developed. The simulation results were evaluated in terms of the natural frequency of the vibrating system and the corresponding phase difference between the motions of the sensing points symmetrically located on the measuring tube. The simulations were conducted on comparison between water and viscous liquid with flow rates spanning the laminar and turbulent regions. The effects of viscosity on mass flow measurement by CMFs are discussed in details. The findings in the simulations can be used for further compensation of deviation due to viscosity effects.
License type:
PublisherCopyrights
Funding Info:
Description:
ISSN:
2010-4286
2010-4294
Files uploaded:

File Size Format Action
luo-apcomiscm2013-1075.doc 971.50 KB DOC Open